Follow these steps to recalibrate the Stratus 2 or 2S if calibration issues persist:
-
Position the Device:
- Place the Stratus 2/2S on a level surface or mount it in its usual aircraft position.
- Turn the Stratus 2/2S on.
-
Connect to WiFi:
- Ensure the iPad is connected to the Stratus 2/2S WiFi network.
-
Adjust Settings:
- Open ForeFlight Mobile.
- Navigate to More > Devices > Stratus.
- Turn On the switch labeled "Ignore Mfg. AHRS Settings."
-
Power Cycle the Stratus:
- Turn the Stratus off, wait 15 seconds, then turn it back on.
- Avoid moving, tilting, or bumping the device after powering it on.
-
Reconnect to WiFi:
- Reconnect the iPad to the Stratus 2/2S WiFi network.
-
Revert Settings:
- Go back to More > Devices > Stratus in ForeFlight Mobile.
- Turn Off the "Ignore Mfg. AHRS Settings" switch.
-
Confirm Calibration:
- Open the Maps page and display Synthetic Vision.
- Gently tilt the Stratus 2/2S to confirm that Synthetic Vision responds correctly.
This process should resolve persistent calibration issues and restore proper Synthetic Vision functionality.